部分喷嘴关闭对预旋供气系统供气参数影响的实验研究
雷昭1,刘高文1,王俊凇1,顾伟2,霍雨2,郑龙席1
1.西北工业大学 动力与能源学院,陕西 西安 710072;2.中国航发商用航空发动机有限责任公司,上海 200241
摘要:
为了研究部分喷嘴流路关闭对预旋供气系统供气流量和供气温度等特性参数的影响,在部分喷嘴流路打开和关闭工况下进行了实验研究。研究结果表明:随着喷嘴压比增大,以几何流通面积定义的喷嘴流量系数先增大后基本保持不变,转动对喷嘴流量系数的影响在1.6%以内,可以忽略;在系统压比为1.30时,由于阀门关闭不严和关闭后预旋腔腔压的变化,供气流量降幅是喷嘴几何流通面积降幅的67.8%~81.8%,实验状态下阀门关闭会导致供气温度降低约1.2~2.4K。
关键词:  预旋供气系统  阀门  部分喷嘴关闭  供气流量  供气温度
DOI:10.13675/j.cnki.tjjs.190714
分类号:V231.3
基金项目:国家科技重大专项(2017-III-0011-0037)。
Experimental Investigations on Effects of Partial Nozzle Closure on Air Supply Parameters in Pre-Swirl Air Supply System
LEI Zhao1, LIU Gao-wen1, WANG Jun-song1, GU Wei2, HUO Yu2, ZHENG Long-xi1
1.School of Power and Energy,Northwestern Polytechnical University,Xi’an 710072,China;2.AECC Commercial Aircraft Engine Co.,LTD,Shanghai 200241,China
Abstract:
In order to study the effects of partial nozzle flow path closure on the characteristic parameters such as air supply mass flow rate and temperature of the pre-swirl air supply system, experiments were carried out under conditions that partial nozzle flow path was open and closed. The results show that as the nozzle pressure ratio increases, the nozzle discharge coefficient defined by the geometric flow area increases first and then remains basically unchanged. The influence of rotation on the discharge coefficient of the pre-swirl nozzle is within 1.6%, which can be ignored. When the system pressure ratio is 1.30, due to the valve is not closed tightly and the variation of pressure in the pre-swirl cavity after closing the valve, the amplitude reduction of air supply mass flow rate is 67.8% ~ 81.8% of that of nozzle geometric flow area, which is less than that of nozzle geometrical flow area. Closing the valve causes the air supply temperature to decrease about 1.2~2.4K in the experimental state.
Key words:  Pre-swirl air supply system  Valve  Partial nozzle closure  Air supply mass flow rate  Air supply temperature